Vulcan-Hart GRC35 Service Manual Page 45

  • Download
  • Add to my manuals
  • Print
  • Page
    / 47
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 44
– 45 –
F-25114 Rev.A (07-03)
GR SERIES GAS FRYERS - TROUBLESHOOTING
SOLID STATE OR COMPUTER CONTROL HARNESS PIN-OUTS
INTERFACE CONTROL BOARD PIN-OUTS
FRYMATE (DUMP STATION) WITH OPTIONAL HEATER
SYMPTOM POSSIBLE CAUSES
No heat. 1. Unplugged.
2. Power switch off or inoperative.
3. Main circuit breaker off or open.
4. Malfunctioning heat assembly.
PIN NO. INPUTS PIN NO. OUTPUTS
3
P1 24VDC Left Basket Lift P6 Heat Demand Triac (24VAC)
2
P2 24VDC Right Basket Lift P7 System Ground
P3 24VDC Heat Demand Control P8 24VAC Left Basket Lift
3
P4 Control Common (-) P9 24VAC Right Basket Lift
3
P5 Heat Demand Triac (24VAC)
P10 Relay Contacts (24VAC)
1
——
NOTES: 1. Relays connected internally. 2. To “TH” Terminal on gas valve (main). 3. To basket lift relay coils.
PIN NO. INPUTS PIN NO. OUTPUTS
3
E1-1 24VAC Hot E1-8 24VDC (+) Heat Demand
E1-2 24VAC Neutral
1
E1-9 Not used at this time
2
E1-3 Probe High (red) E1-10 24VDC (+) Left Basket Lift
E1-4 Probe Low (white) E1-11 24VDC (+) Right Basket Lift
E1-5 Drain Valve Interlock (24VAC) N.O. E1-12 No connection
E1-6 Ignition Status (24VAC)
E1-7 Relay DC (-) Common
NOTES: 1. Connected to ground internally. 2. Available for external buzzer output (24VDC). 3. Outputs to
Interface Control Board.