SECTION lll
TROUBLE SHOOTING
Uneven heating, sides burning A) Temperature too low.
B) Improper operation of broiler.
C) Fluctuating gas pressure.
To much top heat A) Temperature too high.
B) Faulty ventilation.
C) Excessive heat input.
D) Overrated (pressure too high or orifice too large).
.
Uneven heat side to side A) Appliance not level side to side.
B) Burner is improperly installed.
Uneven heat front to back A) Appliance not level front to back.
Dried out products A) Melting time is too long or product is too close
to the burner.
B) Overrated (gas pressure too high or orifice is
too large).
Pilot outage A) Pilot flame is too low.
B) Restriction in pilot orifice.
Poor ignition A) Insufficient gas input.
B) Poor air to gas adjustment.
C) Restriction in pilot orifice.
D) Restriction in main burner ignition port.
E) Pilot adjustment is incorrect.