MODEL C24EA - DRAIN BOX
F25213 (May 2006) Page 12 of 52
CLOSE-UP FROM RIGHT SIDE OF STEAMER
Adjustment
1. Reinstall striker with slot pointing upward and
hand tighten nut only.
2. Close door to center striker in front panel
mounting hole.
3. Open door and check striker slot for horizontal
alignment. The slot on striker must be kept
horizontal in order for door latch to catch
properly and latch.
4. Once proper slot alignment has been set, hold
striker close to its base then tighten the striker
nut. Be careful not to damage striker slot when
tightening or door may not latch properly.
NOTE: Do not over-tighten nut. If over-tightened,
striker may turn and change alignment.
NOTE: If door does not open easily, add shims
between striker and cabinet front. When adding
shims make certain that door gasket seals properly
and steamer does not leak. Remove shims as
necessary until leaking stops.
DRAIN BOX
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
REMOVAL AND REPLACEMENT
1. Turn off machine to drain steam generator tank.
Allow steamer to complete drain cycle.
A. Turn off water supply.
2. Disconnect the drain plumbing from drain box
outlet fitting.
3. Remove the RIGHT AND LEFT SIDE PANELS
as outlined in COVERS AND PANELS.
NOTE: Use plumbing sealant when reinstalling
condensate thermostat.
4. Disconnect the condensate thermostat electrical
wiring.
A. Remove the condensate thermostat from
drain box.
5. Disconnect the cooling solenoid and cooking
compartment drain hoses.
NOTE: The steam generator drain hose is accessed
from right side of machine.
6. Disconnect the steam generator drain hose.
7. Remove the nuts securing drain box to back
plate at rear of steamer.
8. Remove drain box from steamer.
9. Reassemble parts removed in reverse order.
10. Check steamer for proper operation and leaks
around condensate thermostat and hose
connection points.