MODEL C24EA - COVERS AND PANELS
F25213 (May 2006)Page 7 of 52
SCREW LOCATION
REAR PANEL
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1. Remove screws securing top cover to rear
panel and rear panel to steamer frame.
NOTE: If incoming plumbing or drain interferes with
rear panel removal, turn off water supply and
disconnect plumbing to machine.
2. Remove LEFT SIDE PANEL.
3. Disconnect vacuum relief hose from fitting.
4. Pull bottom of rear panel away from machine
and plumbing.
5. Reassemble parts removed in reverse order.